Stat Profile Prime Plus Critical Care Analyzer
- Deskripsi
- Spesifikasi
- Video Produk
- Support
- Download Browsure
New Technologies Simplify Use and Offer Additional Tests
Stat Profile Prime Plus is a comprehensive, whole blood critical care analyzer that combines blood gases, electrolytes, metabolites, CO-Oximetry, and 34 calculated results in a simple, compact analyzer. Prime Plus combines maintenance-free, component cartridge technology for sensors and reagents with patented, new, maintenance-free, and non-lysing whole blood CO-Oximetry technology.
Prime Plus results are produced rapidly, a complete test menu panel in about one minute, and are combined with bidirectional connectivity, a robust data management system, and comprehensive cybersecurity protection.
Measure : PO2, PCO2, Ph, Hct, tHb, Na, Cl, K, TCO2, iCa, iMg, Glu, Lac,
Urea (BUN), Creatinine, GFR, SO2, O2HB, COHb, MetHb, HHb, tBil, and HbF
Critical Care Test Menu | : | Methodology |
pH | : | Direct ISE |
PCO2 | Severinghaus | |
PO2 | Amperometric | |
SO2% | Optical, reflectance | |
Hematocrit | Conductivity/Na+ correction | |
Na+ | Direct ISE | |
K+ | Direct ISE | |
Cl- | Direct ISE | |
TCO2 | Direct ISE | |
Ca++ | Direct ISE | |
Mg++ | Direct ISE | |
Glucose | Enzyme/Amperometric | |
Lactate | Enzyme/Amperometric | |
Urea (BUN) | Enzyme/Amperometric | |
Creat | Enzyme/Amperometric |
CO-Oximetry Test Menu | : | HHb, deoxyhemoglobin | O2Hb, oxyhemoglobin |
MetHb, methemoglobin | COHb, carboxyhemoglobin | ||
tHb, total hemoglobin | SO2 %, oxygen saturation | ||
O2 Ct, oxygen content | O2Cap, oxygen capacity | ||
tBil, total bilirubin | FHb, fetal hemoglobin |
Measured / Range | : | pH | : 6.50 - 8.00 |
(H+ : 316.23 - 10.00 mmol/L) | |||
PCO2 /TCO2 | : 3.0 - 200 mmHg (0.4 - 26.6 kPa) | ||
PO2 | : 5.0 - 765 mmHg (0.66 - 102.0 kPa) | ||
SO2% | : 30 - 100 % (0.3 - 1.00) | ||
Hct | : 12% - 70% | ||
Na+ | : 80 - 200 mmol/L | ||
K+ | : 1 - 20 mmol/L | ||
Cl- | : 50 - 200 mmol/L | ||
Ca++ | : 0.1 - 2.7 mmol/L (0.8 - 10.8 mg/dL) | ||
Mg++ | : 0.1 - 1.5 mmol/L | ||
Glucose | : 0.8 - 28 mmol/L (15 - 500 mg/dL) | ||
Lactate | : 0.3 - 20 mmol/L (2.7 - 178 mg/dL) | ||
Urea (BUN) | : 0.5 - 17.2 mmol/L (3 - 100 mg/dL) | ||
Creatinine | : 17.6 - 1056 mmol/L (0.2-12 mg/dL) | ||
HHb | : 0 to 100% | ||
O2Hb | : 0 to 100% | ||
MetHb | : 0 to 100% | ||
COHb | : 0 to 100% | ||
SO2% | : 0 to 100% | ||
O2Ct | : 0 to 34.75 vol. % | ||
O2Cap | : 0 to 34.75 vol. % | ||
tBil | : 0.5 - 35.1 mg/dL | ||
tHb | : 5 - 25 g/dL | ||
sHb | : Alert > 1.5% | ||
BarP | : 400 - 800 mmHg (53.3 - 106.7 kPa) |
Calculated Parameter | : | eGFR | A-aDO2 | Ca++/Mg++ Ratio |
HCO3- | a/A | Normalized Ca++ | ||
TCO2 | PO2/FIO2 | Normalized Mg++ | ||
BE-ecf | Anion Gap | Osmolality | ||
BE-b | SBC | O2 Cap | ||
O2Ct | Base Excess | Hemoglobin | ||
A | O2 Saturation | A O2 Saturation |
pH/PCO2/PO2 Corrected to Patient Temperature | ||
Respiratory Index (If % FIO2 value entered) | ||
Actual Bicarbonate | ||
Standard Bicarbonate |
Special Calculated Tests (CO-Oximeter Required) | |||
Tests | Resolution | ||
A-v DO2 | 0.1 mmHg (0.01 kPa) | ||
CaO2 | 0.1 mL/dL (0.01 kPa) | ||
CcO2 | 0.1 mL/dL (0.01 kPa) | ||
P50 | 0.1 mmHg (0.01 kPa) | ||
C(a-v)O2 | 0.1 mmHg (0.001 kPa) | ||
Cv02 | 0.1 mmHg (0.001 kPa) | ||
Qsp/Qt | 0.1 mmHg (0.001 kPa) |
Measuring Technology | : | Direct Ion Selective Electrode ( Na, K, Cl, iCa, iMg, pH ) |
All sensor combined in a single MicroSensor card | ||
New MicroSensor Card Technology, accuracy, No Maintenance, and | ||
Complete electrolyte profile | ||
Acceptable Samples | : | Whole blood (heparinized), serum/plasma, arterial, |
mixed venous, capillary, CSF, dialysate | ||
Sample Size | : | 135 microlitres whole blood |
Measuring Time | : | 60 seconds |
Complete Management Reports | : | Calibration Report |
Cartridge Log Report | ||
Daily Sample Log Report | ||
Edit Log Report | ||
Error Log Report | ||
Maintenance Log Report | ||
Operator Setup Report | ||
Patient Report | ||
Levey-Jennings QC Report | ||
QC Corrective Actions Report | ||
QC Data Report | ||
QC Statistics Report | ||
QC Setup Report | ||
Sample Audit Log Report | ||
Calibration | : | Fully automatic two-point calibration every 2 hours; userselectable |
Single-point calibration every 45 minutes or with each sample | ||
Manual calibration initiated at any time. | ||
Interfaces | : | ASTM Protocol, via serial RS232 TCP/IP, POCTIA |
Communication Protocols | : | ASTM, HL7 or POCT1-A2 connectivity formats |
Data Capture | : | 25 cm color LCD touch screen display multilingual, |
QC statistics | ||
onboard data management, automatic sampler, integrated | ||
capillary adapter, optional barcode scanner, QC data storage, | ||
optional mobile cart with UPS | ||
Dimentions and weight | : | Height: 45.7 cm (18.2 in) Width: 35.6 cm (14.2 in) |
Depth: 39.1 cm (15.5 in) Weight: 15.88 kg (35 lb) without reagent Packs |
Silahkan hubungi kontak dibawah ini untuk pertanyaan seputar produk