Stat Profile pHOx Ultra
- Deskripsi
- Spesifikasi
- Video Produk
- Support
- Download Browsure
Using a unique combination of advanced optical and electrode technology, the Stat Profile pHOx analyzer series offer essential blood gas and critical care test menus in the smallest analyzers currently available. The three-test Stat Profile pHOx Basic offers the standard blood gas profile of pH, PCO2, and PO2. The six-test Stat Profile pHOx menu adds measured hematocrit, hemoglobin, and oxygen saturation to provide a complete picture of lung function and oxygen status.
Stat Profile pHOx Plus adds glucose, sodium, potassium, and a choice of chloride or ionized calcium, resulting in an ideal critical care menu in a small, space-saving instrument. Stat Profile pHOx Plus C offers both chloride and ionized calcium. Stat Profile pHOx Plus L menu includes lactate.
The Most Comprehensive Critical Care Analyzer
One analyzer, up to 20 tests
No other blood gas analyzer can match the clinical value of pHOx Ultra, which provides up to 20 critical care tests from one small, 210-microliter sample in only 2 minutes. Other partial test panels are available in less than one minute. Measured tests include: pH PCO2 PO2 SO2% Na K iCa iMg Cl Glucose BUN/Urea Creatinine Lactate Hct Hb O2Hb HHb COHb MetHb tBil
Customized Menus
pHOx Ultra can be custom configured with as few as 5 tests to as many as 20 tests to satisfy the exact test menu requirements of each department. However the complete test menu does not have to be run on each sample. Up to 30 specific user-defined subsets (panels) can be created for patient populations such as pulmonary, surgical, pediatric, or emergency care.
Measured Parameters | : | pH, pCO2, pO2, SO2%, Hb, Hct, Na, K, Glucose, Lactate, iCa, Cl, Mg++ |
BUN, and Creatinine. |
Measured / Range | : | pH | : 6.50 - 8.00 | Na | : 80 - 200 mmol/L |
pCO2 | : 3.0 - 200 mmHg | K | : 1 - 20 mmol/L | ||
pO2. | : 0 - 800 mmHg | Cl | : 50 - 200 mmol/L | ||
SO2% | : 0 - 100 % | iCa | : 0.1 - 2.7 mmol/L | ||
Hb | : 4.0 - 24 g/dL | Glu | : 15 - 500 mg/dL | ||
Hct | : 12 % - 70 % | Lac | : 0.3 - 20 mmol/L | ||
Mg++ | : 0.1 - 1.5 mmol/L | ||||
BUN | : 3 - 100 mg/dL | ||||
Creatinine | : 0.2 - 20 mg/dL | ||||
Barometric : 450 - 800 ± 2 mmHg |
Calkulated Parameters | HCO3 | Ca++/Mg++ Ratio | |
TCO2 | BUN/Creatinine Ratio | ||
BE-ecf | PO2/FIO2 | ||
BE-b | Normalized Ca++ | ||
SBC | Normalized Mg++ | ||
A-aDO2 | O2 Content | ||
A | O2 Capacity | ||
a/A | Respiratory Index (If % FIO2 value entered) | ||
Anion Gap | eGFR | ||
Osmolality | P50 | ||
pH/PCO2/PO2 Corrected to Patient Temperature |
Measuring Technology | : | Ion Selective Electrodes ( pH, Na, K, Cl, iCa, Mg++ ) |
Enzyme / Amperometric ( Glucose, Lactate & Creatinine)) | ||
Enzime / Direct ISE (BUN) | ||
Severinghause (pCO2) | ||
Amperometry ( pO2 ) | ||
Conductivity ( Hematocrit ) | ||
Optical, Reflectance Photometry ( Oxygen Saturation ) | ||
Conductivity/Na+ correction ( Hematocrit ) | ||
Multi Wavelength reflectance/conductivity correction (Hemoglobin) | ||
Acceptable Samples | : | Whole Blood (heparinized), arterial, mixed venous, capillary |
Sample Throughput | : | 38 samples per hour |
Sample Size | : | 150 microliters whole blood, Full Panel |
60 microliters whole blood micro sample for Blood Gases/pH | ||
Acceptable Container | : | Syringes, Capillaries, Vacuum Tubes |
Temperature Control | : | Thermostatting 37°C ±0.1°C |
Calculated | : | Total CO2, Oxygen Content, A, A-aDO2, a/A, R (pO2/FIO2) Actual - |
Bicarbonate, Standard Bicarbonate, Base Excess ( ecf ) , Anion Gap | ||
Base Excess (blood), pH, pCO2, pO2 Values corrected to - | ||
patient temperatures, Osmolality, Normalized Ca++ & Mg++ | ||
BUN/Creatinine Ratio, Ca++/Mg++ Ratio | ||
Data Capture | : | Full color, 12.1 inch touch screen, multilingual |
On Board QC Statisic | ||
On Board Data management | ||
Universal ASTM and HL7 Communication protocols | ||
Auto Flag On Abnormal & Panic | ||
Bar Code Compatible (Optional) | ||
Integrated Capillary Adapter | ||
Automatic Reagent Management System | ||
Optional mobile cart with UPS | ||
Complete Management Reports | : | Calibration Report |
Cartridge Log Report | ||
Daily Sample Report | ||
Edit Log Report | ||
Error Log Report | ||
Maintenance log Report | ||
Operator setup Report | ||
Patient Report | ||
Levey-Jennings QC Report | ||
QC Corective Actions Report | ||
QC Data Report | ||
QC Statistics Report | ||
QC Setup Report | ||
Sample Audit Log Report | ||
Interfaces | : | ASTM Protocol, via serial RS232 TCP/IP, POCTIA |
ASTM standard & HL7 Protocol | ||
Calibration | : | Selectable single point calibration every 45 minutes or with each sample |
Selectable fully automatic two point calibration every 2 hours | ||
Stand by mode with automatic wake-up can be used to conserved | ||
reagents | ||
Manual calibration initiated at any time | ||
Certifications | : | ISO 13485, Quality System, Registration, CSA, TUV, IVDD |
CE Self Declared, CSA, TUV, Complies to EN 61010, EN 50081,82, | ||
Integrated RiLiBakm compliant QC module | ||
Dimentions and weight | : | 56.7(W) X 43.8(D) X 43.7(H) cm, 27.7 kg without reagent |
Calculated Parameters | • Alveolar Oxygen (A) | |
• Arterial Alveolar Oxygen Tension Gradient (AaDO2) | ||
• Arterial Alveolar Oxygen Tension Ratio (a/A) | ||
• Actual Bicarbonate | ||
• Anion Gap | ||
• Base Excess of blood (BE-b) | ||
• Base Excess of extracellular fluid (BE-ecf) | ||
• BUN/Creatinine Ratio | ||
• Bicarbonate level (HCO3-) | ||
• Fractional Oxyhemoglobin (FO2Hb) | ||
• Glomerular Filtration Rate (GFR) | ||
• Hemoglobin (Hb) | ||
• Ionized Calcium/Ionized Magnesium Ratio | ||
• Normalized Ionized Calcium | ||
• Normalized Ionized Magnesium | ||
• Osmolality (Osm/kg) | ||
• Oxygen Content (O2Ct) | ||
• Oxygen Saturation (SO2%) | ||
• Oxygen Capacity (O2Cap) | ||
• P50 (measure single point) | ||
• pH, PCO2, PO2 (corrected to patient temperature) | ||
• •Q sp/ •Q t (physiological shunt - requires 2 samples: mixed venous and arterial) | ||
• Respiratory Index (RI - uses entered %FIO2 or default value of 20.9) | ||
• Standard Bicarbonate Concentration (SBC) | ||
• Total Carbon Dioxide (TCO2) | ||
Electrical Voltage | 220V, 1 phase, 50Hz |